30 VX76 SOFTWARE USER MANUAL
+ Channel - fixture’s channel number.
+ Address - fixture’s DMX universe/address. The DMX universe and address is expressed with dot notation, for
example, the first address of universe 0 (A) would be 0.1.
+ Lamp Curve - specifies lamp dimmer curve setting (if applicable): Fast Bottom, Fast Top, Full at 1%, Hot Patch,
IES Square Law, Slow Bottom, or Slow Top.
+ Focus - options for swapping and/or reversing pan and tilt.
+ Location - for use with 3D graphic features. Refer to "X, Y, Z Locations" on page 323.
+ Orientation - for use with 3D graphic features. Refer to "3D Orientation" on page 324.
+ DMX Offset - sets DMX offset channels between fixtures.
Note: When entering the universe/address, a decimal point must ALWAYS be used even if only one value is provided.
For example if entering both values, the entry would be [
universe#.address#
]. If entering only the universe, the entry
would be [
universe#
.]. If entering only the address, the entry would be [.
address#
].
Entering Patch Commands
A patch command has the following format:
+ [Patch] [Chan] channel# [At] universe#.address#
If the channel number or DMX address is not included, the luminaire will be patched at the next channel or address.
For example, to patch a luminaire at channel 10 as the first channel in DMX universe 2, enter the following command:
+ [Patch] [Chan] 10 [At] 2.1 [Enter]
A [Patch] [Enter] immediately after this will patch channel 11 with the same luminaire type at the next available DMX
address in universe 2 (as long as channel 11 does not already exist).
Remember to change the luminaire type if necessary before pressing [Enter].
Luminaires are automatically located in the Plan View. The luminaire icons can be moved in the Plan View display
while patch edit is enabled.
Patching a range of luminaires can be accomplished with the following syntax:
+ [Patch] [Chan] start# [Thru] end# [At] universe#.address#
Patching Multi-Channels - Conventionals and Scrollers
Conventionals and scrollers can be patched to multiple DMX channels:
+ [Patch] [Chan] chan# [At] universe#.address# [Thru] address# + address#
Vue de la page 45