VX76 SOFTWARE USER MANUAL 119
From Keypad
Note: All Presets have a discrete number which is used when accessing Presets from the keypad. Presets maintain
this number, even when given another label.
Store a new Preset:
Step 1. Select required channels.
Step 2. Using manual controls, set all required parameters.
Step 3. Filter attributes as required using Filter Display window.
Step 4. Press [Store] [Preset] [n] [Enter]
or
[Store] [Preset] [n] [Label] xxxxxxEnter/Accept (where n is the
discrete Preset number).
Add new channels to a Preset:
Step 1. Select required channels.
Step 2. Press [Store] [Preset] [n] [Enter]
or
[Store] [Preset] [n] [Label] xxxxxxEnter/Accept (where n is the
discrete Preset number).
Delete a Preset:
Note: If cues are referenced in a Preset, the Preset cannot be deleted, but it can be moved or copied.
Step 1. Select all channels in that Preset palette.
Step 2. [Delete] [Preset] [n] [Enter]. The display will now show this as an "empty" Preset.
Recall a Preset:
Step 1. Select required channels (only selected channels that have data stored in that Preset will be affected).
Step 2. Press [Preset] [n] [Enter] (where n is the discrete Preset number).
Preset Global Delete
A preset can be deleted for all channels using the command line. Use the following syntax:
+ [Delete] [Preset] # [Delete] [Enter]
A confirmation screen will appear while using this command:
Note: If the preset is linked to a cue, an alert box will appear stating that the action is not allowed.